For California multifamily retrofits, Merino Alpha is the best place to start: it combines 120V power, independent room control, Wi-Fi remote access and a $3,800-per-unit price that includes installation.That combination directly addresses the constraints that can make apartment electrification difficult: limited electrical capacity, scarce outdoor space, and a budget that has to work across an entire building.
The strongest fit is a building that needs independent room-by-room heating & cooling. If you're a building owner, here are four reasons to put Merino at the top of your wishlist.
Merino Alpha plugs into a 120V outlet and uses less than 7.5 Amps. Where the existing wiring and circuit are suitable, that can reduce the need to run new circuits, open finished walls or find additional breaker space.
The low current also matters when evaluating shared circuits. NEC Section 440.62(C) includes a shared-circuit provision for qualifying cord-and-plug-connected room air conditioners: the equipment’s marked current must not exceed 50% of the branch-circuit rating when other specified loads are supplied. Half of a 15-amp circuit is 7.5 amps, so Alpha’s current draw is below that threshold. That exception makes a dedicated circuit unnecessary in a qualifying installation, which can significantly reduce your overall project costs.
For an older apartment building with limited panel space, avoiding unnecessary electrical work can be a major advantage. Equipment selection should start with actual room loads, not an oversized system chosen “just in case.” Oversizing can add electrical demand that pushes a project toward a panel or service upgrade.
For an owner facing a service-upgrade estimate in the hundreds of thousands of dollars and a schedule extended by months, a correctly sized, lower-power heat pump like Merino Alpha is worth evaluating before accepting the expense of an oversized system.
Merino gives apartments room-by-room temperature control without a separate outdoor unit. Residents can adjust the spaces they use, while owners avoid having to find condenser locations for each room-level system.
This is particularly useful in dense urban buildings, where roof, courtyard and façade space are already spoken for. Merino’s through-wall design removes the separate condenser and external refrigerant line-set arrangement, helping preserve usable outdoor space and limit the visual impact of the retrofit. Exterior vents and installation details still need to be planned and approved.
Compare that with a proposal using a separate single-zone mini-split for each apartment: condenser placement, supports, line routing and service access can multiply across the building. Those requirements can make that particular design expensive or difficult to accommodate.
With Merino, Apartment A can cool while Apartment B heats at the same time. Each room’s Merino unit operates independently, so a resident’s choice of heating or cooling does not depend on a neighbor’s preference. The same flexibility applies between rooms in one apartment, without adding separate outdoor condensers.
California’s energy requirements include dwelling-unit thermostat provisions, with exceptions and alternative control arrangements. Merino’s room-level approach gives the design team a practical and affordable temperature control option.
Merino connects to Wi-Fi and allows building owners to control units remotely. For properties where the owner pays the building’s electricity bill, that creates a practical way to manage temperature settings without visiting every apartment.
Remote access is especially relevant when an owner wants to keep heating and cooling settings within a reasonable operating range. It brings temperature management into the ongoing operation of the property, rather than treating the retrofit as a hardware purchase alone.
Merino’s flat-rate price is $3,800 per heat pump (plus tax), including the equipment and basic professional installation. Owners can use that clear starting point to develop a building budget and prepare an estimate for a rebate agency without first untangling separate hardware and installation prices.
Confirm the complete scope before submitting a funding application. Permitting, electrical work, and other nonstandard work may be additional. A clear, itemized estimate can reduce avoidable back-and-forth with a rebate administrator, but program eligibility, funding and approval timing remain the administrator’s decisions.
Merino is particularly compelling when the project needs modest electrical demand, individual comfort control and no separate outdoor condensers. Its flat-rate basic installation pricing also gives owners a useful foundation for comparing proposals and seeking funding.
Start with a representative unit and the building’s electrical information. Confirm room loads, wall locations, circuit capacity, exterior details and control needs, then build a repeatable plan for the remaining apartments. If those checks align, Merino can turn a complicated electrification proposal into a room-by-room retrofit.
Book a site visit with Merino to schedule a complementary assessment. We can help evaluate the fit and prepare a project-specific scope.